Model Name :

6545XT LC/Q-TOF

MADE IN:

Agilent

SPECIFICATION

The Agilent 6545XT Q-TOF LC/MS is a liquid chromatograph-quadrupole time-of-flight mass spectrometer. Combining with Agilent 1290 Infinity II LC system it delivers the highest level of efficiency. It is designed for untargeted sample analysis, and it delivers sensitivity, resolution, mass accuracy, isotopic fidelity, and speed in one measurement. This system can handle multiple workflows in biomolecules characterization, such as examining intact proteins, mapping peptide sequences or analyzing post-translational modifications. With design innovation specifically for large molecule analysis, the 6545XT LC/Q-TOF gives you accurate mass measurements down to low ppm levels. The instrument has a mass range that extends up to 30,000 m/z and the resolution of 50000. Optimizing your system for intact proteins is easy with SWARM autotune. This system accurately profile major and minor proteoforms with time-of-flight technology offering new levels of sensitivity and clarity to intact protein mass spectrometry.

Parameter

Parameter

MS Accuracy, positive <0.8 ppm RMS in 10 replicates
MS Accuracy, negative <0.8 ppm RMS in 10 replicates
MS/MS Sensitivity >1,500:1 ppm RMS in 10 replicates
MS/MS Accuracy, positive <2.0 ppm RMS in 10 replicates
MS/MS Accuracy, negative <2.5 ppm RMS in 10 replicates
Intact protein accuracy <10 ppm RMS in 10 replicates
Mass resolving power >50,000 FWHM at m/z 2,722
Mass range 50–30,000 m/z
Spectral acquisition rate, MS 50 spectra/second
Spectral acquisition rate, MS/MS 30 spectra/second

Application – Single-molecule, Metabolomics, Proteomics, Intact Protein Analysis, Peptide Sequence Mapping

Charges-

Services Charges (For measurements only) in INR (₹)
(Per polarity per sample basis/measurement only) KIIT group Users Educational Institutes Industry
LC (Extra charges @ 300/30min run) 350 450 1050
LCMS (≤15min) (Extra charges @ 300/30min run) 450 600 1200
LC-MS/MS (Extra charges @ 400/30min run) 600 900 1800
Metabolite Profiling (only MS) (Extra charges @ 500/30min run) 3000 4000 9000
Targeted Metabolite Profiling (MS/MS) (Extra charges @ 500/30min run) Standards to be provided by the user 4500 6000 13500
For any other specialized experiment and / or analysis, please contact [email protected]